![dsc dls panel could not be identified dsc dls panel could not be identified](http://dlshelp.dsc.com/images/d/d7/PC-Link-06.png)
18:25:07.013 - setPanelMessage(): Panel Message Set to - 609: General status of the zone - open. 18:25:07.012 - updateChannel(): Panel Channel UID: dscalarm:panel:envisalink:panel:panel_message 18:25:07.010 - parseAPIMessage(): Message Received (609003) - Code: 609, Name: Zone Open, Description: 609: General status of the zone - open., Data: 003 18:25:03.239 - DSC Alarm Polling Task - 'dscalarm:envisalink:envisalink' is ONLINE
![dsc dls panel could not be identified dsc dls panel could not be identified](https://data2.manualslib.com/first-image/i17/81/8026/802580/dsc-power-832.jpg)
18:24:58.230 - DSC Alarm Polling Task - 'dscalarm:envisalink:envisalink' is ONLINE 18:24:53.219 - DSC Alarm Polling Task - 'dscalarm:envisalink:envisalink' is ONLINE 18:24:48.210 - DSC Alarm Polling Task - 'dscalarm:envisalink:envisalink' is ONLINE 18:24:46.362 - handleCommand(): Command Received - dscalarm:zone:envisalink:zone3:zone_bypass_mode ON. 18:24:43.192 - DSC Alarm Polling Task - 'dscalarm:envisalink:envisalink' is ONLINE 18:24:42.197 - handleCommand(): Command Received - dscalarm:zone:envisalink:zone3:zone_bypass_mode OFF. 17:57:15.696 - DSC Alarm Polling Task - 'dscalarm:envisalink:envisalink' is ONLINE 17:57:10.904 - dscAlarmEventRecieved(): Thing - dscalarm:panel:envisalink:panel Command - CommandAcknowledge 17:57:10.901 - setBridgeConnection(): Setting Bridge to ONLINE 17:57:10.901 - setPanelMessage(): Panel Message Set to - 500: A command has been received successfully. 17:57:10.899 - updateChannel(): Panel Channel UID: dscalarm:panel:envisalink:panel:panel_message 17:57:10.897 - parseAPIMessage(): Message Received (500000) - Code: 500, Name: Command Acknowledge, Description: 500: A comman$ 17:56:10.415 - ***Checking 'dscalarm:panel:envisalink:panel' - Status: ONLINE, Initialized: true 17:56:10.414 - DSC Alarm Polling Task - 'dscalarm:envisalink:envisalink' is ONLINE 17:56:06.010 - handleCommand(): Command Received - dscalarm:zone:envisalink:zone3:zone_bypass_mode ON. 17:56:05.840 - dscAlarmEventRecieved(): Thing - dscalarm:panel:envisalink:panel Command - CommandAcknowledge 17:56:05.837 - setBridgeConnection(): Setting Bridge to ONLINE 17:56:05.836 - setPanelMessage(): Panel Message Set to - 500: A command has been received successfully. 17:56:05.834 - updateChannel(): Panel Channel UID: dscalarm:panel:envisalink:panel:panel_message In the log: 17:56:05.833 - parseAPIMessage(): Message Received (500000) - Code: 500, Name: Command Acknowledge, Description: 500: A comman$ I can also see the status of the Bypass LED in OH, status of the zones, etc. I can Arm and Disarm the alarm, so the basic communication works. I checked with my old config, and it works just fine, nice “B” appears on the keypad when I toggle the setting with an iPhone. Item is defined as: Switch ZONE3_BYPASS_MODE "Z3 Bypass Mode" (DSCAlarmZones) Īnd toggling the switch has no effect on the panel. I am using binding openhab> bundle:list|grep -i dscĢ23 │ Active │ 80 │ 2.05280907 │ DSCAlarm Binding I cannot make the DSC panel zones bypass work with the new binding in OH 2.4 I am porting (finally) my working OH 1.9 setup to new platform.